WebSep 7, 2024 · Doug Horgan recommends asking the masons to handle this step because masons typically have the right material on site. Step by step: 1) Run membrane down the side of the block and onto the roof … WebDescription: Stepped flashing is used where a sloped roof meets a masonry wall. A typical occurrence is where a brick chimney rises above a roof. The details shown concentrate on such chimney flashings, but apply to other wall conditions. ... Chimney Cricket … This condition is similar to Detail 9.3I, except it is not possible to install through … 9.9A. Ventilator Flashing. This detail illustrates a method of flashing a … 9.2C. New Flashing in Existing Brick Wall. This detail shows how new copper … 9.10. Dormers. Description: The conditions for flashing the junction of a dormer and … For roof pitches of 6" or more per foot the flashing extends at least 9" under the … 9.4. Ridges and Hips. Description: There are many ways to construct copper ridge … 9.12B. Typical Eave Flashing. This detail is typically used for flashing eaves of non …
GAF TPO Roofing Systems
WebWhile the flashing for caps and copings may have a different prime function from normal usage, it is still necessary to provide weepholes immediately above the flashings to convey the water collected on the flashing out of the wall, unless exterior flashing is used. Weepholes should be spaced at a maximum of 24 in. (600 mm) WebWall Details: PDF Download: DWG Download: 3-3: Low Flashing Height Grid Strip: Wall Details: PDF Download: DWG Download: 3-3A: Surface Mounted Counterflashing: Wall … tiger line shapefile download
Brick Masonry Details, Caps and Copings, Corbels and …
WebAug 1, 2024 · Flexible wall underlay cut and dressed into the opening on all sides (or, for proprietary RAB systems, follow the specific installation details). Flexible flashing tape applied to the top corners of window and door openings and extended 100 mm from the corners both horizontally and vertically (see Figure 1). WebWeep holes or open head joints should be located a maximum of 32 in. (813 mm) apart. Flashing at lintels and sills (shown in Figures 2 and 3, respectively) is very similar. Although not shown, vents can be installed … WebCarlisle SynTec Systems has a variety of flashings available to assist in flashing any oddly-shaped penetrations or tying together dissimilar roofing systems. ... Carlisle's Certified Fabricated Accessories and Pressure-Sensitive Accessories are used in a variety of details, and videos have been created to educate applicators in installation ... tigerline ferry route map